Test Entry - Detail


Clonazepam


General
  Clinical Use: Therapeutic drug monitoring. Clonazepam (a benzodiazepine)is an antiepileptic medication.
  Availability: Samples are batched and tested once a week.
  Aliases/Synonyms: Klonopin,   Rivotril,  
  Code: CLON
  Handling Instructions (to laboratory): Send sample chilled.
  Hyperlink:
  Reference Interval:
Therapeutic range: 20 - 70 ug/L.
Toxicity may be seen at concentrations greater than 80 ug/L.


Collection Requirements
  Container: Serum, no gel (RED),  
  Sample Type: See container
  Minimum Collection Volume: 2mL
  Collection Instructions: Collect sample prior to dose as trough level.
Record date, time and dosage of last dose on request form.


Processing Requirements
  Alternate Containers:
Lithium Heparin, No Gel (DKGNLITH)
  Processing Instructions: Centrifuge and separate sample.
  Minimum Assay Volume: 1mL
  Stability:
  Transport Instructions (to testing laboratory): Send sample chilled.


Testing Locations
  Performed at:
Section Department Site Contact Phone
- Laboratory SSWPS-Royal Prince Alfred Hospital (02) 9515 8279


Last Updated : 03-10-2020 10:54