Test Entry - Detail


Oestradiol-LCMS


General
  Clinical Use: LCMS method is used to measure oestradiol in <12yo males and females.
  Availability: Samples are batched and tested once a week.
  Aliases/Synonyms: E2 (Paediatric-Ultra Sensitive),   Estradiol-LCMS,   Oestrogen (Paediatric-Ultra Sensitive),   Paediatric Oestradiol,   Paediatric Oestrogen,   Sensitive E2,   Sensitive Oestradiol,   Ultrasensitive E2,   Ultrasensitive Oestradiol,  
  Code: EXX
  Handling Instructions (to laboratory): Send sample chilled.
  Hyperlink:
  Reference Interval:
Males:
0y  to  <10y    <10
10y to  <12y    <50
12y to  <15y    <100
15y to  <18y    <120
18y to  <120y   <160

Females:
0y  to  <8y     <20
8y  to  <10y    <60
10y to  <12y    <240
12y to  <120y:
Follicular          110-450
Mid-cycle           550-1300
Luteal              350-800
Post-menopausal     40-130

Ref ARUP LCMS 2013, Quest Diagnostics 2017 and PathWest review 2017.


Collection Requirements
  Container: Serum, no gel (RED),  
  Sample Type: See container
  Minimum Collection Volume: 0.5mL
  Collection Instructions:


Processing Requirements
  Alternate Containers:
Lithium Heparin, No Gel (DKGNLITH)
EDTA (LAVENDER)
  Processing Instructions:
  Minimum Assay Volume: 100uL
  Stability: 7 days chilled; 2 months frozen
  Transport Instructions (to testing laboratory): Send sample chilled.


Testing Locations
  Performed at:
Section Department Site Contact Phone
Special Chemistry Biochemistry QEII Medical Centre 6383 4114


Last Updated : 29-12-2022 10:51