Test Entry - Detail

CAT


General
  Clinical Use: The Thrombogram describes the concentration of thrombin in clotting plasma and is therefore a general physiologic function test of the thrombotic hemostatic system. The CAT measures thrombotic as well as bleeding tendency.
  Availability: Samples are batched and tested once a month.
  Aliases/Synonyms: Calibrated Automated Thrombogram,   Thrombin Generation Assay,  
  Code: CAT
  Handling Instructions (to laboratory): Send whole sample ambient.
Send separated sample frozen on dry ice.
  Hyperlink:
  Reference Interval:
Refer to report or laboratory


Collection Requirements
  Container: Sodium Citrate-3.2% (BLUE),  
  Sample Type: See container
  Minimum Collection Volume: 2.7mL
  Collection Instructions: If sample will not reach laboratory within 4 hours of collection, it must be double centrifuged, separated and frozen.
Non-medicare rebateable item. All patients except Public, VA and Pensioners must pay $35.55 upfront.


Processing Requirements
  Alternate Containers:
  Processing Instructions:
  Minimum Assay Volume: 1mL
  Stability: 4 hours ambient
  Transport Instructions (to testing laboratory): Send separated sample frozen on dry ice.


Testing Locations
  Performed at:
Section Department Site Contact Phone
Coagulation Haematology Fiona Stanley Hospital 6152 8135


Last Updated : 28-10-2021 13:33