Test Entry - Detail

QuantiFERON CMV


General
  Clinical Use: First-line Interferon-gamma release assay against CMV antigens, and used for the monitoring of CMV.
  Availability: Samples are tested Monday-Friday.
  Aliases/Synonyms: Interferon Gamma Screening Test for CMV Status,  
  Code: QFCMV
  Handling Instructions (to laboratory): Send sample ambient.
  Hyperlink:
  Reference Interval:
Mitogen >=0.5 IU/mL
CMV Specific Antigens <0.25 IU/mL


Collection Requirements
  Container: Quantiferon CMV Kit (QUCMV),  
  Sample Type: See container
  Minimum Collection Volume: 3 x 1mL
  Collection Instructions: Collection kits contain 3 tubes which are pre-coated with a set amount of reagent.
Tubes must be filled to the marked line and then inverted 10 times to mix.
Tubes that are under or over filled will be rejected for testing.


Processing Requirements
  Alternate Containers:
  Processing Instructions: Incubate samples for 16-24 hours within 16 hours of collection.
Centrifuge samples for 15 minutes at 3000 RCF.
Enter relevant incubation start and end dates and times into SoftLab.
  Minimum Assay Volume: 3mL
  Stability: 16 hours ambient (pre-incubation); 3 days ambient (post-incubation/pre-centrifugation); 4 weeks chilled (post-centrifugation)
  Transport Instructions (to testing laboratory): Send sample ambient.


Testing Locations
  Performed at:
Section Department Site Contact Phone
- Immunology Fiona Stanley Hospital 6152 8006


Last Updated : 07-01-2025 11:09