Thyroid Stimulating Immunoglobulin
|
|
General
|
| |
Clinical Use:
|
Thyroid Stimulating Immunoglobulin can be used to diagnose and monitor suspected Graves' hyperthyroidism or orbitopathy when TRAB is negative or not consistent with clinical picture. |
| |
Availability:
|
|
| |
Aliases/Synonyms:
| Thyroid Stimulating Ab, TSI, |
| |
Code:
|
TSI |
| |
Handling Instructions (to laboratory):
|
Send sample chilled. |
| |
Hyperlink:
|
|
| |
Reference Interval:
|
< 0.55 IU/L
|
Collection Requirements
|
| |
Container:
|
Serum Sep. Tube-SST (GOLD), |
| |
Sample Type:
|
See container |
| |
Minimum Collection Volume:
|
1mL |
| |
Collection Instructions:
|
|
Processing Requirements
|
| |
Alternate Containers:
|
|
|
|
|
Serum, no gel (RED) |
| |
Processing Instructions:
|
Centrifuge and separate sample. |
| |
Minimum Assay Volume:
|
500uL |
| |
Stability:
|
7 hours ambient; 6 days chilled |
| |
Transport Instructions (to testing laboratory):
|
Send sample chilled.
Duty Biochemist to review request and TRAB result prior to approval. |
Testing Locations
|
| |
Performed at:
|
|
Section
|
Department
|
Site
|
Contact Phone
|
| - |
Laboratory |
Western Diagnostic Pathology |
9317 0999 |
|
Last Updated : 21-12-2022 15:01 |