Anti-Streptolysin O Titre


General
  Clinical Use: Used for the detection of antibodies to Streptolysin O when a patient is suspected of having a Group A streptococcal infection (acute rheumatic fever, acute glomerulonephritis).
  Availability: Samples are batched and tested three times a week.
  Aliases/Synonyms: ASOT,  
  Code: ASO
  Handling Instructions (to laboratory): Send sample chilled.
  Hyperlink:
  Reference Interval:
<=200 IU/mL


Collection Requirements
  Container: Serum Sep. Tube-SST (GOLD),  
  Sample Type: See container
  Minimum Collection Volume: 1mL
  Collection Instructions:


Processing Requirements
  Alternate Containers:
Lithium Heparin-PST (GREEN)
  Processing Instructions:
  Minimum Assay Volume: 500uL
  Stability: 5 days chilled
  Transport Instructions (to testing laboratory): Send sample chilled.


Testing Locations
  Performed at:
Section Department Site Contact Phone
Special Chemistry Biochemistry QEII Medical Centre 6383 4114


Last Updated : 22-11-2023 07:53